VMware vCenter authentication bypass CVE-2026-123890 exploited, CISA warns

Critical 9.8KEVCVE-2026-123890

VMware vCenter authentication bypass CVE-2026-123890 exploited, CISA warns

Broadcom has fixed a critical authentication bypass in VMware vCenter, tracked as CVE-2026-123890. The flaw is in the VMware Directory Service. According to CISA, it lets an unauthenticated attacker with network access to vCenter bypass authentication and gain unauthorized access to the system. VMware Telco Cloud Platform and Telco Cloud Infrastructure are also affected.

The vulnerability carries a CVSS 3.1 score of 9.8 (Critical). CISA added it to its Known Exploited Vulnerabilities (KEV) catalog on 20 November 2026, one day after it was published in the NVD, confirming that attackers are exploiting it in the wild. Because vCenter controls entire virtualization environments, administrators should treat this as an emergency patch.

What’s affected

The NVD record lists these affected VMware vCenter versions and their fixed releases:

  • 9.1.x: versions before 9.1.1.0200
  • 9.0.x: versions before 9.0.2.0200
  • 8.0: versions before 8.0 U3m
  • 5.x: versions before 5.2.5

The following products are also listed as affected. The vendor refers customers to knowledge base article KB463116 for these:

  • VMware Telco Cloud Platform 3.0, 4.x, 5.0.x, 5.1.x and 5.2
  • VMware Telco Cloud Infrastructure 3.0

The advisory data we reviewed does not state fixed versions for the Telco Cloud products. Check the Broadcom advisory and KB463116 for guidance.

How serious is it

The vendor-assigned CVSS vector is CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H. In plain terms:

  • Attack vector: Network. The flaw can be exploited remotely by anyone who can reach vCenter over the network.
  • Attack complexity: Low. No special conditions are needed.
  • Privileges required: None. The attacker does not need an account.
  • User interaction: None. No administrator has to click or approve anything.
  • Impact: High for confidentiality, integrity and availability. A successful attacker could read data, change configuration and disrupt the system.

The weakness is classified as CWE-288, Authentication Bypass Using an Alternate Path or Channel. This means the login check can be sidestepped through a route that does not enforce it.

Is it being exploited?

Yes. CISA has confirmed active exploitation and added CVE-2026-123890 to the KEV catalog on 20 November 2026. Whether the flaw is used in ransomware campaigns is listed as unknown.

US federal civilian agencies must act by 23 November 2026, a deadline of just three days. CISA’s required action is to:

  • apply mitigations according to vendor instructions, in line with BOD 26-04 (Prioritizing Security Updates Based on Risk) and CISA’s Forensics Triage Requirements;
  • follow the applicable BOD 26-04 guidance for cloud services, or stop using the product if mitigations are unavailable;
  • evaluate each asset’s internet exposure.

What to do

  • Upgrade vCenter now to 9.1.1.0200, 9.0.2.0200, 8.0 U3m or 5.2.5, depending on your release line, as described in the Broadcom advisory.
  • Telco Cloud customers should follow the guidance in KB463116 and the Broadcom advisory.
  • Restrict network access to vCenter so that only trusted management networks can reach it. vCenter should never be exposed to the internet.
  • Check for compromise. Exploitation is confirmed, so patching alone may not be enough. Review vCenter access logs and look for unexpected accounts or configuration changes. CISA’s reference to forensics triage suggests investigating systems that were exposed before patching.
  • Review the third-party threat intelligence report in the references for mitigation and detection guidance.

References