Danfoss AK-SM 800A path traversal flaw CVE-2023-25914 exploited, CISA warns

High 8.8KEVCVE-2023-25914

Danfoss AK-SM 800A path traversal flaw CVE-2023-25914 exploited, CISA warns

A path traversal vulnerability in Danfoss AK-SM 800A Series system managers, tracked as CVE-2023-25914, lets authenticated attackers retrieve and read system files on the underlying server through the device’s XML interface. According to the NVD description, the information that can be read this way “can lead to a full system compromise.”

The flaw was published in August 2023 and is rated 8.8 (High). On 2026-11-25, CISA added it to its Known Exploited Vulnerabilities (KEV) catalog, which means CISA has evidence that it is being exploited. Organizations still running affected units should treat this as urgent.

What’s affected

NVD lists Danfoss AK-SM800A versions earlier than 3.3 as affected. CISA’s KEV entry refers to the product as the Danfoss AK-SM 800A Series.

The records do not explicitly name a fixed release. The affected range suggests that version 3.3 and later are not affected, but the advisory data provided here doesn’t confirm this. Administrators should check Danfoss’s security advisory for the confirmed fixed version before planning upgrades.

How serious is it

NVD scores the vulnerability 8.8 out of 10 (High) with the vector CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H. In plain terms:

  • Network attack vector, low complexity: it can be exploited remotely over the network without special conditions.
  • Low privileges required: the attacker needs a valid account on the device, but not an administrative one.
  • No user interaction: no one else has to click or open anything.
  • High impact on confidentiality, integrity and availability: reading system files can expose information, such as credentials or configuration, that gives an attacker full control of the system.

The weakness is classified as CWE-22, Improper Limitation of a Pathname to a Restricted Directory (‘Path Traversal’).

Is it being exploited?

Yes. CISA has confirmed exploitation by adding CVE-2023-25914 to the KEV catalog on 2026-11-25. Whether the flaw has been used in ransomware campaigns is listed as unknown.

Under BOD 26-04, US federal agencies must apply mitigations in line with vendor instructions and follow CISA’s BOD 26-04 guidance and its Forensics Triage Requirements. Where mitigations are unavailable, agencies must follow the applicable BOD 26-04 guidance for cloud services or stop using the product. CISA also says stakeholders are responsible for evaluating each asset’s internet exposure. The due date is 2026-11-28, only three days after the vulnerability was added to the catalog.

What to do

  • Identify affected units: inventory all AK-SM 800A Series devices and check their software versions. Anything below 3.3 is affected according to NVD.
  • Upgrade: apply the update named in Danfoss security advisory DSA-2023-08-01 (linked below). Confirm the fixed version there.
  • Restrict exposure: make sure these controllers and their XML interface are not reachable from the internet. Limit network access to trusted management hosts, for example through segmentation or a VPN.
  • Review accounts and credentials: exploitation requires authentication, so remove unused accounts and enforce strong, unique passwords. Because the flaw can expose system files, consider rotating credentials stored on or used by affected devices.
  • Check for compromise: given confirmed exploitation, review device and network logs for unexpected access to the XML interface. Federal agencies should follow CISA’s Forensics Triage Requirements.