Frappe HRMS versions from 16.14.0 up to but not including 16.20.1 send product usage (telemetry) events during certain HR transactions without checking whether the site has telemetry turned off. The flaw is tracked as CVE-2026-126315. According to the advisory record, some of these events also carry more detail than they need to. Values such as leave type names, claimed amounts and appraisal scores can be transmitted during normal use, with no user action, even on sites where administrators have disabled telemetry.
The vulnerability record classifies the issue as an exposure of private personal information (CWE-359). The CVE Numbering Authority scored it 9.8 out of 10 (Critical). It is not listed in CISA’s Known Exploited Vulnerabilities catalog. The issue is fixed in version 16.20.1.
What’s affected
- Product: Frappe HRMS
- Affected versions: 16.14.0 and later, before 16.20.1
- Not affected: 16.20.1
The record lists 16.14.0 as the first affected version. It does not say whether releases before 16.14.0 send telemetry in the same way. The flaw shows up during normal HR activity, so any site running an affected version may be sending this data, whatever its telemetry setting.
How serious is it
The CNA assigned a CVSS 3.1 base score of 9.8 (Critical) with the vector CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H. In plain terms, that vector describes a flaw reachable over the network, with low complexity, needing no privileges and no user interaction. It also rates the impact on confidentiality, integrity and availability as high.
Readers should weigh the score against the description. The published description is about sensitive HR values being sent out without consent. That is a confidentiality and privacy problem. The description does not mention any way to change data or disrupt the system, so the high integrity and availability ratings are not explained by the record. The NVD status is still “Received”, which means NVD has not yet done its own analysis, and the score may be revised.
For HR teams, the practical concern is data protection. Leave types can hint at medical or personal circumstances. Claimed amounts and appraisal scores are confidential employee information. Sending them off-site after telemetry has been disabled may matter for privacy obligations within your organisation.
Is it being exploited?
As of the record date (2026-11-17), CVE-2026-126315 is not in CISA’s Known Exploited Vulnerabilities catalog. The supplied records contain no reports of exploitation. Note that this flaw does not need an attacker to act: the data is sent during normal use of the software.
What to do
- Upgrade to Frappe HRMS 16.20.1, which the advisory data lists as unaffected.
- Check which version you run. Any instance on 16.14.0 or later but below 16.20.1 should be treated as having sent telemetry regardless of its settings.
- Review outbound network access from your HRMS servers. Where your environment allows it, limit outbound connections to destinations you need until the upgrade is done. The records do not name the telemetry endpoint, so check the vendor advisory for details.
- Involve your privacy or data protection team. Employee data may have been sent while telemetry was believed to be off. They can decide whether any assessment or notification steps apply.
- Read the vendor advisory linked below for any further guidance from the Frappe maintainers.